V1.0.1 2024/4/17 R1: Support VBS series PLC R2: VS1 support XY 128 points increased to 192 points, EC card which can reach 3 V0.84.13 2024/1/18 Q: Back up the VS1 project and connect the VS2 PLC. After the backup, the PLC Type of the file is wrong. Q: VSENET2 Configuration, check the same IP Port V0.84.10 2023/11/30 Q1: VS3, D2580, read from PLC, nickname is wrong V0.84.9 2023/11/10 Q1: SFC, RST S, missing component V0.84.8 2023/10/26 Q1: When clicking on the connection Type setting, the OK button will not be enabled. Q2: If paste the SFC ladder, it will crash. V0.84.7 2023/8/30 Q1: When reading the PLC project, it will crash due to incorrect component information Q2: Ladder Form, Shift Mark, copy, will crash V0.84.5 2023/8/22 Q1: Construct Ladder with Real Compare Contact, wrong Q2: There is no SRET error in the ladder, and the Cursor should stop behind the STL form. V0.84.4 2023/7/10 Q1: Ladder, monitor, C200Z0, wrong value Q2: COM Port Setup, Modbus Mapping Form, VSM will crash V0.84.3 2023/6/19 Q1: Entry Applied Function, reference, click on the blank of the Instruction Type, wrong. V0.84.2 2023/6/6 V0.84.1 2023/5/23 Q1: Print Ladder, wrong row height V0.84.0 2023/5/16 R1: Support $+, $MOV two Instructions R2: Compare Ladder V0.83.0 2023/3/2 R1: Open VB/VH file, convert some Instructions, special M and special D R2: Ladder, mouse wheel + Shift = scroll horizontally R3: Component Entry, if the component name is readonly, it will turn gray R4: Component Entry, in the component number field, only the component number can be input; in the component nickname field, only the component nickname can be input R5: Component information, display VZ, special M and special D items R6: Resource usage status, display VZ items Q7: The search form crashes Q8: When monitoring, open the PLC information, press close, it will crash Q9: In PLC copy mode, it will crash Q10: Monitoring, PLC power off, missing error message Q11: monitoring page, click on the head of the column, add D0-49, it will crash V0.82.2 2022/10/3 Q1: Large files, the Cross reference is very slow to open V0.82.1 2022/9/8 Q1: Search form crashes V0.82.0 2022/9/5 Q1: monitoring, Ladder, index VZ, VZ negative, display value error Q2: After Running Edit, the ladder form was closed V0.81.2 2022/7/20 Q1: BMOV S,D,n; n is not added to the Resource using Q2: EC3D10, Cross reference, wrong order V0.81.1 2022/6/20 Q1: LINK, MBUS Table Wrong V0.81.0 2022/5/13 R1: HoldArea Form can open VB file V0.80.5 2022/3/22 Q1: With the same program unit number, when read from PLC, the program block will disappear V0.80.3 2022/3/9 V0.80.2 2022/2/17 Q1: Maximize the form, monitor, click another ladder form, there is no monitoring value in the output area V0.80.1 2022/1/26 R1: MBUS table, the station number is limited to 247, changed to 255 V0.80.0 2022/1/13 Q1: Ladder, delete 11 cells, leaving a blank row, rebuild the ladder after parsing, the next row will go up, and then undo, the deleted data will overwrite the data in the upper row Q2: INT D700 D1400, when the ladder is monitoring, the value is wrong; D1400 is 16-bit, not 32-bit Q3: Disable the network card, there is no available network card, open the connection Type setup, it will crash Q4: VS3, ladder, input Mov D0 U10G1, there should be no error message V0.79.5 2021/12/6 Q1: Connection setup, choose USB, choose COM10, the connection fails, or the last time COM1 Q2: Monitor pages, paste Dec32, but change Dec Q3: Monitor pages, View Nickname, the monitoring component X40-47 is added, and there is an error message Q4: Monitor Component, during monitoring, an ON pulse is generated, which is changed from 10ms to 200ms V0.79.4 2021/11/5 Q1: Adobe Acrobat Reader DC, 64-bit, cannot be opened by pressing Help V0.79.3 2021/10/29 Q1: monitor components, D9070 is added, and it is not preset to 32-bit V0.79.2 2021/9/14 Q1: Ladder, Ctrl-Home, row height are wrong V0.79.1 2021/9/6 Q1: EC Card Replace form, component information is missing when undo R2: Monitor pages form, special D, when adding a range, actively divide 16-bit, 32-bit R3: Monitor Component form, multi-selection added V0.79.0 2021/8/27 R1: COM Port Setup, CP2's Baud Rate add 1.5Mbps option R2: Connection Setup, Ethernet adds myLink Server option R3: Add EC Card Replace form, and modify the multiple components replace form V0.78.4 2021/7/19 R1: Support VS3 partial Instructions V0.78.2 2021/7/13 Q1: Cross reference, Add Z0 K14 Z0, no Z0 driven V0.78.1 2021/6/2 Q1: Component information, Save As CSV, Win7 and WinXP cannot be saved as UTF8 V0.78.0 2021/5/31 R1: Component information, a. CSV can be imported, and the separator of the archive CSV is changed to a comma; b. Copy and paste with component number in the row; V0.77.0 2021/4/26 Q01: Press F1, no opening Help Q02: Prog1 STL, no RET, Prog2 general ladder diagram, after compiling, the result is wrong V0.76.1 2021/3/18 Q1: 2 LadderMasterS, LadderMasterS A, click [File].[Backup], click [This Project], it will jump to LadderMasterS B Q2: Compare Contact, Real2 components cannot be compared with 32-bit components V0.76.0 2021/1/29 R1: VSENET2 Configuration