Product

Product


New Generation VS1 series

  • Control points : 10~512 points.
  • PLC main unit offers 10、14、20、24、28、32, various of options.
  • The capacity size is 64K steps, Built-in a Flash ROM program memory, no back-up battery required, maintenance-free design.
  • Built-in high-speed USB communication port, communication transmission is superb fast.
  • Built-in RS-485 communication port to support various protocol of MODBUS.
  • 8 high-speed input points, 4 high-speed output points, full support for high-speed performance.
  • Support memory card function, effectively solve system maintenance problems.
  • Support expansion modules and expansion card function, system expansion is flexible.

Multi-Functional VB series

  • Control points : 14~256 points.
  • The Main Unit has a built-in Multi-Functional Display which displays error message and contents of data registers..
  • The capacity size is 8K/16K steps.
  • Plenty of instructions, including: floating point, PID and compare instructions, etc.
  • MODBUS protocol provided.
  • Main unit offers AC / DC24V power input types and Relay Output, NPN Transistor and PNP Transistor input type options.
  • Two I/O connection types: Barrier terminal block or ATX connector.
  • Full Communication Function, meet complex communication needs
    1. The Main Unit has an RS-232 interface (CP1),   it can be connected with a computer,   HMI (Human Machine Interface), MODEM   or SCADA.
        (Supervisory Control And Data Acquisition)
    2. Multiple communication cards and expansion   modules provide RS-232, RS-485 interfaces. The   system maximum can be expanded up to 19   communication ports.
    3. Perform a variety of protocols. e.g.   Support Computer Link, CPU Link, Parallel   Link, Easy Link, MODEM Communication ,   MODBUS(Master/Slave) Communication   and Non-Protocol Communication.
    4. PLC can be connected with a computer,   all HMI brands or SCADA to become a local   area network monitor.
  • Numerous kinds of Special Modules, Supplied for various Special Applications
    1. Analog I/O module,VB-4AD/VB-2DA/VB-4DA/   VB-6A/VB-3A
    2. Temperature Input Module, VB-8T/VB-4T/   VB-4PT/VB-2PT
    3. Temperature Control module, VB-2LC
    4. Pulse Output Positioning Module, VB-1PG
    5. High-speed Counter Module, VB-1HC
    6. 2-Channel Valve control module VB-2VC
    7. Serial Link Communication Module. VB-1COM

Ultra Valuable VH series

  • Control points : 10~128 points.
  • Built-in Multi-Functional Display which displays error message.
  • The capacity size is 4K steps.
  • Built-in a Flash ROM program memory, no back-up battery required, maintenance-free design.
  • The password protection function can prevent any unauthorized program upload, thus the intellectual property right can be protected.
  • Plenty of instructions including arithmetic operation and compare instructions.
  • Interrupt Input and High-Speed Counter.
  • PLC main unit offers 10、14、20、24、28、32、40、60 points, various of options.
  • Fully Communication Function:
    1. built-in RS-232 interface,data can be   transferred between the plc and computer、   HMI and MODEM
    2. RS-232 and RS-485 communication interface,   maximum can be expanded up to 3   communication ports.
    3. PLC can be connected with a computer, all HMI   brands or SCADA to become a local area network   monitor.
113 - 122 of 122 << Previous 28
View Picture Item No. View Picture Model No. Specification User Manual
VSM-32MT-DI
VSM Main Unit
16 DI (DC 24V, 4×200 kHz + 4×50 kHz); 16 DO (100mA NPN transistor, Y0~Y3 200 kHz); 32K words project memory; 3 Expansion Card sockets; DIO Expansion & 8 Special Modules available; I/O by IDC connector.
Expansion Module
VH-8YR
Expansion Module
Expansion
Module
8 points Relay Output
VS-2DA-EC
Special Function Expansion Card
Analog Output Card: 2 channel (12-bit) outputs, each channel could input either -10~+10V, 4~20mA or -20~+20mA; non-isolated
Expansion Module
VH-8XYR
Expansion Module
Expansion
Module
4 points DC 24V Signal Input; 4 points
Relay Output
VS-4A-EC
Special Function Expansion Card
Analog I/O card: 2 channel (12-bit) inputs + 2 channel (12-bit) outputs, each channel could input/output either -10~+10V, 4~20mA or -20~+20mA; non-isolated
Extension Cable of Expansion Unit/Module
VHEC-050
Extension Cable of Expansion Unit/Module
Extension Cable of
Expansion Unit
Module
VH Series PLC Expansion Extended cable;
Length: 50cm 19.7”
VS-3ISC-EC
Special Function Expansion Card
Inverter Speed Control Card: 3 channel (0.1% resolution) voltage outputs; totally isolated for each channel
VS-2TC-EC
VS-4TC-EC
Special Function Expansion Card
Thermocouple Temperature Input Card: 2 /4 channel (K, J, R, S, T, E, B or N type thermocouple, 0.2~0.3℃ resolution) inputs; non-isolated
VS-1PT-EC
VS-2PT-EC
Special Function Expansion Card
PT-100 Temperature Input Card: 1 /2 channel (3-wire PT-100, 0.1℃ resolution) input; non-isolated
VS3-32M★-D
VS3 Mian Unit
16 DI (DC 24V, 4×200 kHz + 4×50 kHz); 16 DO ★(Y0~Y3 200 kHz at NPN transistor model);
64K words project memory; 3 Exp. Card sockets; DIO Exp. & 16 Special Modules available;